A few months ago, I decided to invest in a UPS (Uninterruptible Power Supply) to safeguard my electronic devices during power outages. It worked perfectly fine for the first 4 to 5 months, but then suddenly, I noticed it wasn’t charging anymore. Naturally, I turned to Google to figure out what might be going wrong. Unfortunately, despite all my searching, I couldn't find any reliable information or articles that addressed the exact issue I was experiencing.

The most puzzling thing was that all the indicator lights on the UPS started blinking at the same time, and no amount of Googling gave me an answer to what that meant. I thought about contacting Luminous, the brand of my UPS, and registered a complaint on their website. However, a week passed with no response, and I was left to figure things out on my own.

Luckily, one of my friends suggested that the blinking lights could be due to a "hanging" issue. He explained that, much like laptops or smartphones, sometimes a UPS needs a restart to fix internal glitches. But unlike electronic gadgets where restarting is as simple as pressing a button, a UPS requires a bit more work. I had to find a way to “restart” it manually, which was a completely new concept for me.

The challenge came when I tried to power it down. You can’t just switch it off from the main power switch or disconnect the power cables because, as long as the battery is charged, the UPS continues to draw power from it. This meant that even after turning it off, all the lights on the inverter were still blinking.

It became clear that I needed to disconnect the battery itself to force the restart. That’s where things got a little tricky. I learned the hard way that when disconnecting one of the battery wires – whether it’s the positive or negative terminal – it can cause a small spark. I won’t lie, this gave me a bit of a scare, but after some hesitation, I managed to pull it off. I disconnected the wire, waited for a moment, and then reconnected it.

To my relief, this simple action “restarted” the UPS, and all the blinking lights disappeared. The UPS went back to functioning normally, and it started charging properly again.

The whole experience taught me two valuable lessons. First, sometimes, technical devices like a UPS just need a manual restart to fix minor issues. Second, it's important to approach electrical repairs with caution. The spark I saw during the wire disconnection was a reminder that even small tasks can be risky if you're not careful.

So, if you ever find your UPS acting up with all its lights blinking, try this: disconnect the battery wires, wait for a moment, and reconnect them. Just remember to be cautious when handling any electrical components.

For me, this was a bit of an interesting DIY fix, and it feels great to know that I could troubleshoot the problem myself when no online resources could help. If you're facing similar issues with your UPS, maybe this little trick can save you time and stress too!